Gasman  enkeltgasmonitor gasdetektor

Gasman enkeltgasmonitor gasdetektor

Vare nr: 12-69-318-XS

Gasman fuldfunktionens personlige enkeltgasmonitor er kompakt og letvægts, men er fuldt robust for de hårdeste industrielle miljøer. Med den enkle enkeltknap-funktion har den en stor letlæselig visning af gaskoncentration og hørbare, visuelle og vibrerende alarmer.

2.867,00 DKK2.967,00 DKK per stk.

2.867,00 DKK

(Eks. moms)

3.583,75 DKK3.708,75 DKKper stk.

(Inkl. moms)

Vare ikke til rådighed

Lagervare

Du har endnu ingen indkøbslister

Klik her for at oprette en indkøbsliste
Succes! Produktet er tilføjet til din liste.



Specifikationer

for vare nr.: 18-C-GASMAN

UNSPSC
26131701 Gasdetektorer v. 19.0501
Godkendelse



Beskrivelse

Maximum number of gases detected


Standard battery life


Minimum product weight


Ingress protection level


Gasman is a range of rugged, compact single gas personal monitors designed for use in the toughest environments. Its stunningly compact and lightweight design makes it ideal for use in industries such as oil and gas, chemical plants (with exotic gases), steel works (special CO sensor), hospitality (CO2) and waste and water works.

Weighing just 130g, it is extremely durable, with high impact resistance and dust/water ingress protection, loud 95 dB alarms, a vivid red/ blue visual warning, single-button control and an easy-to-read, backlit LCD display to ensure clear viewing of gas level readings, alarm conditions and battery life. Data and event logging are available as standard, and there is a built-in 30 day advance warning when calibration is due.

Gasman is also available in a safe area CO2 version offering 0-5% carbon dioxide measurement.

Robust

  • Tough polycarbonate housing - protects you in the harshest environments

  • Water and dust resistant to IP65

  • Full overmoulding - high impact resistance

Odoo text and image block
Odoo text and image block

Effective warning

  • 2 levels of instantaneous alarm and TWA alarms for toxic versions - ensures prompt evacuation from hazardous zone

  • 95dB audible alarm

  • Vivid twin red/blue visual alarm - if ambient noise is high, Gasman alerts you by vibrating and with the high impact blue/red LED alarms

  • Internal vibrating alarm

Flexible

  • Versions available for flammable gas, oxygen and toxic gases - gas detector tailored to your requirements

  • Rechargeable versions for all gas types

  • Non-rechargeable versions for oxygen and toxic gases

  • Real-time TWA and peak display options

  • Fully interchangeable intelligent sensor modules

Odoo text and image block
Odoo text and image block

User friendly

  • One button operation - quick and easy to use

  • Backlit display for gas diagnostics and operating status - easy to read

  • Ultra lightweight; just 85g for toxic versions - comfortable to wear

Specifications

 

Size90 x 48 x 24 mm (3.5 x 1.9 x 0.95 ins)
WeightFlammable: 138g (4.9oz)

Toxic: 118g (4.1oz)

Oxygen: 129g (4.6oz)

Carbon monoxide: 139g (4.9oz)

Typical response times (T90)Flammable: 20s

Toxic gas: 20s

Oxygen: 10s 

AlarmsAudible: 95dB; Multiple alarm options let you select distinctive tones for different alarm levels

Visible: Dual colours red/ blue flashing LEDs in a gas hazard

Internal vibrating alarm

DisplayCustom LCD with backlight, with display of gas concentration. Graphic symbols for battery (with proportional indication of remaining operation time), and display mode. Start up indication when calibration is due within 30 days, calibration overdue or service required.

Normal display: Real time gas concentration levels

Display recall: Peak readings and TWA

Data loggingFull timed datalogging with adjustable sample rate, set to 1 min. data rate as default.

900 hours storage at 1 min. interval (54,000 logs), >4800 events

BatteryRechargeable lithium battery for all gas types

Non-rechargeable lithium battery for toxics and oxygen (excluding CO2)

Operating time*Rechargeable: 12 hours minimum for flammable unit

Non-rechargeable: Up to 2 years

SamplingOptional manual aspirator
Operating temperature**-20°C to +65°C (-4°F to +149°F)
Humidity20 to 90% RH
Ingress protectionIP65
ApprovalsEurope: Toxic or O2: ATEX II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0384

Flammable: ATEX II 2G Ex ia d IIC T4 Gb (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0383

International: Toxic or O2: IECEx BAS05.0039

Flammable: IECEx BAS05.0038

North America: CSA Class 1 Groups A,B,C,D Division 1

StandardsEurope: EN60079-0, EN60079-11, EN60079-1

North America: CSA22.2, 152EN50270, EN50271, IEC61508, EN61779, EN45544

PC InterfaceRS232 connection from interface module in charger

RS232/USB converter available

CalibrationGasman can be routinely calibrated using Portables PC software or by using Checkbox IMH
*Operating time will depend on operating pattern and alarm occurrence. Frequent or long lasting alarms and use of the optional confidence beep will reduce battery life.

**Toxic and oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperatures are likely to exceed 40°C (104°F) for extended periods.

 

GasRangeStandard Alarm (UK)
Ammonia (NH3)0-100 ppm25 ppm
Carbon monoxide (CO)0-500 ppm30 ppm
Carbon dioxide (CO2)0-5% vol.0.5% vol.
Chlorine (Cl2)0-20 ppm0.5 ppm
Flammable0-100% LEL20% LEL
Fluorine (F2)0-1 ppm0.1 ppm
Hydrogen (H2)0-2000 ppmN/A
Hydrogen cyanide (HCN)0-25 ppm5 ppm
Hydrogen fluoride (HF)0-10 ppm1 ppm
Hydrogen sulphide (H2S)0-100 ppm5 ppm
Nitric oxide (NO)0-100 ppm25 ppm
Nitrogen dioxide (NO2)0-20 ppm1 ppm
Oxygen (O2)0-25% vol.19% / 23% vol.
Ozone (O3)0-1 ppm0.1 ppm
Phosphine (PH3)0-5 ppm0.2 ppm
Phosgene (COCL2)0-1 ppm0.1 ppm
Sulphur dioxide (SO2)0-20 ppm1 ppm




Tilbehør



Downloads



Stregkoder:


    Print denne side