True

Crowcon - Bump Testing Equipment for Portables - Issue 2

ID: 386
Views
170 Total Views
0 Members Views
170 Public Views
Share on Social Networks
Share Link
Use permanent link to share in social media
Share by mail

Please login to share this document by email.

Embed in your website
Select page to start with

6. Copyright© 2015 Crowcon Detection Instruments Ltd. All rights reserved. Company registered no. 978878 Approval: JM Page 6 Crowcon Technical Note Crowcon Detection Instruments Ltd 172 Brook Drive, Milton Park, Abingdon, Oxfordshire, OX14 4SD, UK Email: customersupport@crowcon.com Web: www.crowcon.com T riple Plus + and D etective + Manual Solution See Technical Note “ PT010 Triple Plus + Gas Response Testing ” C03052 Fixed Flow regulator AC0201 1m standard tubing M04032 A spirator hose (for exhaust) Aspirator Flow Plate

2. Copyright© 2015 Crowcon Detection Instruments Ltd. All rights reserved. Company registered no. 978878 Approval: JM Page 2 Crowcon Technical Note Crowcon Detection Instruments Ltd 172 Brook Drive, Milton Park, Abingdon, Oxfordshire, OX14 4SD, UK Email: customersupport@crowcon.com Web: www.crowcon.com Gasman Manual Solution C01892 Gas test Kit. Contains regulator, tubing, flowplate and Crowmag (Same as T3 Gas test kit, except for flowplate) NB: Bump test gas levels are preset in the instrument’s firmware – these can be changed using PortablesPC . The d efault test gas levels are: O2: 18% volume CO : (500ppm sensor) 100ppm ROW , 250ppm USA H2S : (100ppm sensor) 15ppm CH4: 50% LEL CO2: 2% volume Can also be used for field calibration. For full calibration * or to allow configuration of gas levels , add communications kit C011305 and Portables PC C01832 ( * subject to training). Wall Mount Solution Not Available

1. Copyright© 2015 Crowcon Detection Instruments Ltd. All rights reserved. Company registered no. 978878 Approval: JM Page 1 Crowcon Technical Note Crowcon Detection Instruments Ltd 172 Brook Drive, Milton Park, Abingdon, Oxfordshire, OX14 4SD, UK Email: customersupport@crowcon.com Web: www.crowcon.com Document Reference: GEN072 – Bump Testing Equipment for Portables – Issue 2 Date: 11/06/2018 Document applies to: Crowcon Portables This document pro vides an overview of the bump test accessories available for each portable. D efault / recommended bump te st gas levels are given for instruments with O2, CO, LEL, H2S and CO 2 sensors. For instruments with other sensors plea se check with customersupport@crowcon.com . Abbreviations, ROW: Rest of World. Clip SGD Single Gas Detector Clip SGD docking station C an be configured with Clip SGD Docking Station s oftware which is a free download from our website. ( https://www.crowcon.com/service - and - support/software.html ) Default target gas concentrations (can be changed using software): H 2 S: 25 ppm, CO: 100 ppm, O 2 : 18% Compatible with 60 litr e cylinders . (can also be used for calibration) Manual Solution Spray Gas (flow cap is provided with each SGD Clip , not available sep a rately ) G1 - CO - 100 - N - 12 100 ppm CO G1 - H2S - 25 - N - 12 25 ppm H2S G1 - O2 - 18 - N - 12 18% O2

5. Copyright© 2015 Crowcon Detection Instruments Ltd. All rights reserved. Company registered no. 978878 Approval: JM Page 5 Crowcon Technical Note Crowcon Detection Instruments Ltd 172 Brook Drive, Milton Park, Abingdon, Oxfordshire, OX14 4SD, UK Email: customersupport@crowcon.com Web: www.crowcon.com T4 NB: Bump te sting needs to be enabled in this instrument ’s settings , using Portables Pro 2 . USB communications lead CH0103 or CH0104 required. Manual Solution T4 - CAL - CAP Replacement Bump Cap, comes with T4 anyway! C03052 Fixed Flow regulator AC0201 1m standard tubing CH0103 or CH0104 USB l ead – allows user to enable bump testing, and to use the bump test feature in Portables Pro 2 software. NB: Bump test Gas levels are preset in the instrument Default test gas levels are: O2: 18% volume CO: 100ppm H2S: 1 5ppm CH4: 50% LEL (use QUAD gas) Customer can use these accessories to bump test via the instrument menu , or using the bump test tool in the Portables Pro 2 software ( free download from our website ) . Wall Mount Solution I - TEST for T4 (saves calibration and bump records) Requires demand flow regulator.

3. Copyright© 2015 Crowcon Detection Instruments Ltd. All rights reserved. Company registered no. 978878 Approval: JM Page 3 Crowcon Technical Note Crowcon Detection Instruments Ltd 172 Brook Drive, Milton Park, Abingdon, Oxfordshire, OX14 4SD, UK Email: customersupport@crowcon.com Web: www.crowcon.com Tetra 3 Manual Solution C011062 Gas test Kit . Contains regulator, tubing, flowplate and Crowmag (Same as Gasman Gas test kit, except for flowplate) NB: Bump test gas levels are preset in the I nstrument ’s firmware – these can be changed using PortablesPC. The default test gas levels are: O2: 18% volume CO: (500ppm or dual sensor) 100ppm H2S: (100ppm or dual sensor) 15ppm CH4: 50% LEL CO2: 2% volume (use QUAD or QUINT gas) Can also be used for field calibration. For full calibration* or to allow configuration of gas levels, add communications kit C011305 and Portables PC C01832 . (*subject to training). Wall Mount Solution NB: Bump test gas levels are preset in Instrument firmware – these can be changed using PortablesPC. The default test gas levels are O2: 18% volume CO: (500ppm or dual sensor) 100ppm H2S: (100ppm or dual sensor) 15ppm T3 Gas Tester CH4: 50% LEL CO2: 2% volume (use QUAD or QUINT gas) (This unit contains no electronics, it does not process or store any information) Can perform calibration on bump failure only. No t suitable for full calibration . Requires fixed flow regulator, use of a cylinder holder recommended – see price list for options.

4. Copyright© 2015 Crowcon Detection Instruments Ltd. All rights reserved. Company registered no. 978878 Approval: JM Page 4 Crowcon Technical Note Crowcon Detection Instruments Ltd 172 Brook Drive, Milton Park, Abingdon, Oxfordshire, OX14 4SD, UK Email: customersupport@crowcon.com Web: www.crowcon.com Gas Pro NB: Bump te s ting needs to be enabled in the Gas - Pro’s settings, using Portables Pro 2 . USB communications lead CH0103 or CH0104 required . Manual Solution AC0101 Non - pumped f low Plate C03052 Fixed Flow regulator AC0201 1m standard t ubing M04032 A spirator hose (for exhaust) CH0103 or CH0104 USB lead – allows user to enable bump testing, and to use the bump test feature in Portables Pro 2 software. NB: Bump test Gas levels are preset in the instrument but they can be changed using Portables Pro 2 software Default test gas levels are: O2: 18% volume CO: (500ppm or dual sensor) 100ppm H2S: (100ppm or dual sensor) 15ppm CH4: 50% LEL CO2: 2% volume (use QUAD or QUINT gas) Customer can use these accessories to bump test via the instrument menu , or using the bump test tool in the Portables Pro 2 software ( free download from our website ) . Wall Mount Solution 1 I - TEST for GasPro (saves calibration and bump records) (for instruments with O2/LEL /CO/H2S/CO2 sensors only ) Requires demand flow regulator, c ylinder holder recommended . Can also be used for calibration. Wall Mount Solution 2 Q - TEST (This unit contains no electronics, it does not process or store any information) Requires fixed flow regulator, use of a cylinder holder is recommended , see price list for opti ons. Calibration on bump failure only.

To install this Web App in your iPhone/iPad press and then Add to Home Screen.