Crowcon - Bump Testing Equipment for Portables - Issue 2

GEN072 - Bump Testing Equipment for Portables - Issue 2

Share on Social Networks

Share Link

Use permanent link to share in social media

Share with a friend

Please login to send this document by email!

Embed in your website

Select page to start with

6. Copyright© 2015 Crowcon Detection Instruments Ltd. All rights reserved. Company registered no. 978878 Approval: JM Page 6 Crowcon Technical Note Crowcon Detection Instruments Ltd 172 Brook Drive, Milton Park, Abingdon, Oxfordshire, OX14 4SD, UK Email: customersupport@crowcon.com Web: www.crowcon.com T riple Plus + and D etective + Manual Solution See Technical Note “ PT010 Triple Plus + Gas Response Testing ” C03052 Fixed Flow regulator AC0201 1m standard tubing M04032 A spirator hose (for exhaust) Aspirator Flow Plate

2. Copyright© 2015 Crowcon Detection Instruments Ltd. All rights reserved. Company registered no. 978878 Approval: JM Page 2 Crowcon Technical Note Crowcon Detection Instruments Ltd 172 Brook Drive, Milton Park, Abingdon, Oxfordshire, OX14 4SD, UK Email: customersupport@crowcon.com Web: www.crowcon.com Gasman Manual Solution C01892 Gas test Kit. Contains regulator, tubing, flowplate and Crowmag (Same as T3 Gas test kit, except for flowplate) NB: Bump test gas levels are preset in the instrument’s firmware – these can be changed using PortablesPC . The d efault test gas levels are: O2: 18% volume CO : (500ppm sensor) 100ppm ROW , 250ppm USA H2S : (100ppm sensor) 15ppm CH4: 50% LEL CO2: 2% volume Can also be used for field calibration. For full calibration * or to allow configuration of gas levels , add communications kit C011305 and Portables PC C01832 ( * subject to training). Wall Mount Solution Not Available

1. Copyright© 2015 Crowcon Detection Instruments Ltd. All rights reserved. Company registered no. 978878 Approval: JM Page 1 Crowcon Technical Note Crowcon Detection Instruments Ltd 172 Brook Drive, Milton Park, Abingdon, Oxfordshire, OX14 4SD, UK Email: customersupport@crowcon.com Web: www.crowcon.com Document Reference: GEN072 – Bump Testing Equipment for Portables – Issue 2 Date: 11/06/2018 Document applies to: Crowcon Portables This document pro vides an overview of the bump test accessories available for each portable. D efault / recommended bump te st gas levels are given for instruments with O2, CO, LEL, H2S and CO 2 sensors. For instruments with other sensors plea se check with customersupport@crowcon.com . Abbreviations, ROW: Rest of World. Clip SGD Single Gas Detector Clip SGD docking station C an be configured with Clip SGD Docking Station s oftware which is a free download from our website. ( https://www.crowcon.com/service - and - support/software.html ) Default target gas concentrations (can be changed using software): H 2 S: 25 ppm, CO: 100 ppm, O 2 : 18% Compatible with 60 litr e cylinders . (can also be used for calibration) Manual Solution Spray Gas (flow cap is provided with each SGD Clip , not available sep a rately ) G1 - CO - 100 - N - 12 100 ppm CO G1 - H2S - 25 - N - 12 25 ppm H2S G1 - O2 - 18 - N - 12 18% O2

5. Copyright© 2015 Crowcon Detection Instruments Ltd. All rights reserved. Company registered no. 978878 Approval: JM Page 5 Crowcon Technical Note Crowcon Detection Instruments Ltd 172 Brook Drive, Milton Park, Abingdon, Oxfordshire, OX14 4SD, UK Email: customersupport@crowcon.com Web: www.crowcon.com T4 NB: Bump te sting needs to be enabled in this instrument ’s settings , using Portables Pro 2 . USB communications lead CH0103 or CH0104 required. Manual Solution T4 - CAL - CAP Replacement Bump Cap, comes with T4 anyway! C03052 Fixed Flow regulator AC0201 1m standard tubing CH0103 or CH0104 USB l ead – allows user to enable bump testing, and to use the bump test feature in Portables Pro 2 software. NB: Bump test Gas levels are preset in the instrument Default test gas levels are: O2: 18% volume CO: 100ppm H2S: 1 5ppm CH4: 50% LEL (use QUAD gas) Customer can use these accessories to bump test via the instrument menu , or using the bump test tool in the Portables Pro 2 software ( free download from our website ) . Wall Mount Solution I - TEST for T4 (saves calibration and bump records) Requires demand flow regulator.

3. Copyright© 2015 Crowcon Detection Instruments Ltd. All rights reserved. Company registered no. 978878 Approval: JM Page 3 Crowcon Technical Note Crowcon Detection Instruments Ltd 172 Brook Drive, Milton Park, Abingdon, Oxfordshire, OX14 4SD, UK Email: customersupport@crowcon.com Web: www.crowcon.com Tetra 3 Manual Solution C011062 Gas test Kit . Contains regulator, tubing, flowplate and Crowmag (Same as Gasman Gas test kit, except for flowplate) NB: Bump test gas levels are preset in the I nstrument ’s firmware – these can be changed using PortablesPC. The default test gas levels are: O2: 18% volume CO: (500ppm or dual sensor) 100ppm H2S: (100ppm or dual sensor) 15ppm CH4: 50% LEL CO2: 2% volume (use QUAD or QUINT gas) Can also be used for field calibration. For full calibration* or to allow configuration of gas levels, add communications kit C011305 and Portables PC C01832 . (*subject to training). Wall Mount Solution NB: Bump test gas levels are preset in Instrument firmware – these can be changed using PortablesPC. The default test gas levels are O2: 18% volume CO: (500ppm or dual sensor) 100ppm H2S: (100ppm or dual sensor) 15ppm T3 Gas Tester CH4: 50% LEL CO2: 2% volume (use QUAD or QUINT gas) (This unit contains no electronics, it does not process or store any information) Can perform calibration on bump failure only. No t suitable for full calibration . Requires fixed flow regulator, use of a cylinder holder recommended – see price list for options.

4. Copyright© 2015 Crowcon Detection Instruments Ltd. All rights reserved. Company registered no. 978878 Approval: JM Page 4 Crowcon Technical Note Crowcon Detection Instruments Ltd 172 Brook Drive, Milton Park, Abingdon, Oxfordshire, OX14 4SD, UK Email: customersupport@crowcon.com Web: www.crowcon.com Gas Pro NB: Bump te s ting needs to be enabled in the Gas - Pro’s settings, using Portables Pro 2 . USB communications lead CH0103 or CH0104 required . Manual Solution AC0101 Non - pumped f low Plate C03052 Fixed Flow regulator AC0201 1m standard t ubing M04032 A spirator hose (for exhaust) CH0103 or CH0104 USB lead – allows user to enable bump testing, and to use the bump test feature in Portables Pro 2 software. NB: Bump test Gas levels are preset in the instrument but they can be changed using Portables Pro 2 software Default test gas levels are: O2: 18% volume CO: (500ppm or dual sensor) 100ppm H2S: (100ppm or dual sensor) 15ppm CH4: 50% LEL CO2: 2% volume (use QUAD or QUINT gas) Customer can use these accessories to bump test via the instrument menu , or using the bump test tool in the Portables Pro 2 software ( free download from our website ) . Wall Mount Solution 1 I - TEST for GasPro (saves calibration and bump records) (for instruments with O2/LEL /CO/H2S/CO2 sensors only ) Requires demand flow regulator, c ylinder holder recommended . Can also be used for calibration. Wall Mount Solution 2 Q - TEST (This unit contains no electronics, it does not process or store any information) Requires fixed flow regulator, use of a cylinder holder is recommended , see price list for opti ons. Calibration on bump failure only.

Views

  • 289 Total Views
  • 254 Website Views
  • 35 Embeded Views

Actions

  • 0 Social Shares
  • 0 Likes
  • 0 Dislikes
  • 0 Comments

Share count

  • 0 Facebook
  • 0 Twitter
  • 0 LinkedIn
  • 0 Google+