1. Gasman Portable Gas Detection Equipment l Robust l Effective warning l Flexible l User friendly

2. When lives and property are at risk and you need gas detection equipment that is totally reliable, you need Crowcon. For over 40 years Crowcon has been developing and manufacturing high quality products with a reputation for reliability and technical innovation. Crowcon provide both single gas and multigas monitors for personal monitoring and portable safety applications providing protection against a wide range of industrial gas hazards. Choosing the portable gas detector for your needs Gasman is a range of rugged, compact single gas personal monitors designed for use in the toughest environments. With rugged impact resistant construction and compliance to IP65, Gasman offers a wide range of gases, including six flammable calibration options. Gasman gives an unbeatable combination of powerful loud and bright alarms. Its stunningly compact and lightweight design makes it ideal for use in industries such as oil and gas, chemical, steel works and waste and water works. Gasman is small, light and easy to use. Weighing just 130g, it is extremely durable, with high impact resistance and dust/water ingress protection to IP65. When potentially hazardous levels of gas are detected, the Gasman alerts the user with a loud 95 dB alarm, a vivid red/ blue visual warning and also by vibrating. Gasman features simple, single-button control and has an easy-to-read, backlit LCD display to ensure clear viewing of gas level readings, alarm conditions and battery life. Data and event logging are available as standard, and there is a built-in 30 day advance warning when calibration is due. Gasman Personal single gas monitor Robust Tough polycarbonate housing Water and dust resistant to IP65 Full overmoulding Effective warning 2 levels of instantaneous alarm and TWA alarms for toxic versions 95dB audible alarm Vivid twin red/blue visual alarm Internal vibrating alarm Protects you in the harshest environments High impact resistance Ensures prompt evacuation from hazardous zone If ambient noise is high, Gasman still alerts you by vibrating and with the high impact blue/red LED alarms

3. Please see the back page for full technical specifications. User friendly One button operation Backlit display for gas diagnostics and operating status Ultra lightweight- just 85g for toxic versions Flexible Versions available for flammable gas, oxygen and toxic gases Rechargeable versions for all gas types Non-rechargeable versions for oxygen and toxic gases Real time TWA and peak display options Fully interchangeable intelligent sensor modules Gas detector tailored to your requirements Quick and easy to use Easy to read Comfortable to wear Gas Carbon monoxide (H 2 filtered) Ammonia (NH 3 ) Carbon monoxide (CO) Carbon dioxide (CO 2 ) Chlorine (CL 2 ) Flammable Fluorine (F 2 ) Hydrogen (H 2 ) Hydrogen cyanide (HCN) Gas Hydrogen fluoride (HF) Hydrogen sulphide (H 2 S) Nitric oxide (NO) Nitrogen dioxide (NO 2 ) Oxygen (O 2 ) Ozone (O 3 ) Phosphine (PH 3 ) Phosgene (CCL 2 ) Sulphur dioxide (SO 2 ) Range 0-500ppm 0-100ppm 0-500ppm 0-5% 0-20ppm 0-100% LEL 0-1ppm 0-2000ppm 0-25ppm Range 0-10 ppm 0-100 ppm 0-100 ppm 0-20 ppm 0-25% 0-1 ppm 0-5 ppm 0-1 ppm 0-20 ppm Standard Alarm (UK) 30ppm 25ppm 30ppm 0-5% 0.5ppm 20% LEL 0.1ppm N/A 5ppm Standard Alarm (UK) 1ppm 5ppm 25ppm 1ppm 19/23% 0.1ppm 0.2ppm 0.1ppm 1ppm Gases and Ranges Required ranges and alarms vary by country and application and these can be configured as required. Each gas channel can have two instantaneous alarm levels set. Toxic units also have Time Weighted Average (TWA) alarms. Flammable gas calibration is available for methane, propane, butane, pentane, hydrogen and ethylene as standard. Gasman is also available in a safe area CO 2 version offering 0-5% carbon dioxide measurement. Typical ranges and alarms: Gas Test Kit The Gas Test Kit provides a simple and convenient means of carrying out either bump test or a calibration.

4. www.crowcon.com UK: Tel: +44 (0) 1235 557700 Fax: +44 (0) 1235 557718 Email: sales@crowcon.com US: Tel: +1 859 957 1039 Toll Free: 800 527 6926 Fax: +1 513 957 1044 Email: salesusa@crowcon.us NL: Tel: +31 10 421 1232 Fax: +31 10 421 0542 Email: eu@crowcon.com SG: Tel: +65 6745 2936 Fax: +65 6745 0467 Email: sales@crowcon.com.sg CN: Tel: +86 (0) 10 6787 0335 Fax: +86 (0) 10 6787 4879 Email: saleschina@crowcon.com IN: Tel: +91 22 6708 0400 Fax: +91 22 6708 0405 Email: salesindia@crowcon.com Crowcon reserves the right to change the design or specification of the product without notice. Check www.crowcon.com for updates. Size Weight Typical response times (T 90 ) Alarms Display Display modes Datalogging Battery Operating time* Sampling Operating temperature range** Humidity Ingress protection Approval codes Standard s safety Operation standards PC interface Calibration Accessorie s P01019 GB Issue 10 August 13 Gasman Specification: Flammable Toxic Oxygen Carbon monoxide Flammable Toxic gas Oxygen Audible Visible Vibrating Normal display Display recall Rechargeable Non rechargeable Rechargeable Non rechargeable Europe International North America Europe North America 90 x 48 x 24 mm (3.5 x 1.9 x 0.95 ins) 138g (4.9oz) 118g (4.1oz) 129g (4.6oz) 139g (4.9oz) 20s 20s 10s 95dB Multiple alarm options let you select distinctive tones for different alarm levels Dual colours red/ blue flashing LEDs in a gas hazard Internal vibrating alarm Custom LCD with backlight, with display of gas concentration. Graphic symbols for battery (with proportional indication of remaining operation time), and display mode. Start up indication when calibration is due within 30 days, calibration overdue or service required. Real time gas concentration levels Peak readings and TWA Full timed datalogging with adjustable sample rate, set to 1 min. data rate as default. 900 hours storage at 1 min. interval (54,000 logs), >4800 events Lithium battery for all gas types Lithium battery for toxics and oxygen (excluding CO 2 ) 12 hours minimum for flammable unit Up to 2 years Optional manual aspirator -20 o C to + 65 o C (-4 o F to +149 o F) 20-90% RH IP65 Toxic or O 2 : ATEX II 1G Ex ia IIC T4 Ga (-20OC ≤ Ta ≤ +65 O C) BASEEFA04ATEX0384 Flammable: ATEX II 2G Ex ia d IIC T4 Gb (-20OC ≤ Ta ≤ +65 O C) BASEEFA04ATEX0383 Toxic or O 2 : IECEx BAS05.0039 Flammable: IECEx BAS05.0038 CSA Class 1 Groups A,B,C,D Division 1 EN60079-0, EN60079-11, EN60079-1, 94/9/EC CSA22.2, 152 EN50270, EN50271, IEC61508, EN61779, EN45544 RS232 connection from interface module in charger RS232/USB converter available Gasman can be routinely calibrated using Portables PC software or by using Checkbox IMH Gasman is supplied with an integral alligator clip *Operating time will depend on operating pattern and alarm occurrence. Frequent or long lasting alarms and use of the optional confidence beep will reduce battery life. **Toxic and oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperatures are likely to exceed 40 O C (104 O F) for extended periods.

Views

  • 526 Total Views
  • 475 Website Views
  • 51 Embeded Views

Actions

  • 0 Social Shares
  • 0 Likes
  • 0 Dislikes
  • 0 Comments

Share count

  • 0 Facebook
  • 0 Twitter
  • 0 LinkedIn
  • 0 Google+