1. ARD2 1 00 Remote Methane Leak Detector User Manual

7. ARD2 1 00 Remote Methane Leak Detector User Manual 4 3. Specifications

18. ARD2 1 00 Remote Methane Leak Detector User Manual 15 ☆ When detecting a corner against a high reflectance background, two reflective spotter laser pointers can be observed. At this time , false alarms may be caused, and other angles should be changed to test again to determine whether it is a leak alarm.

6. ARD2 1 00 Remote Methane Leak Detector User Manual 3 2. C omposition The st ructure and accessories of ARD2 1 00 Remote Methane Leak Detector are as follows:

9. ARD2 1 00 Remote Methane Leak Detector User Manual 6 Turn off : Long press the power switch on the front of the device again, the device and the display will be turn ed off. 4.2 Menu Illustration 4.3 Change menu setting Press the MENU key to enter the menu interface. The menu interface is as follows:

8. ARD2 1 00 Remote Methane Leak Detector User Manual 5 4. Operation Instruction 4.1 Turn on and Turn off Turn on : Press and hold the power switch on the front of the device, the display shows the warm - up and start - up interface, and then enter the detection interface. * Note: At this time, only the spotter and detect or laser have been turned on and continue to work.

10. ARD2 1 00 Remote Methane Leak Detector User Manual 7 4.3.1 Alarm S etting On the ma in menu interface, move the cursor with the + and - buttons to select the alarm setting icon, and press the MENU key to enter the alarm setting. Use the + and - keys to change the size of the alarm value. Press MENU to confirm the changes and return to the main menu. 4.3.2 System S etting On the main menu interface, move the cursor with the + and - keys to select the system setting icon, and press MENU enter the system setting.

2. ARD2 1 00 Remote Methane Leak Detector User Manual Qingdao ALLRED Electronics Co., Ltd. mainly produces Remote Methane Leak Detector, Infrared Flammable Gas Detector, Toxic Gas Detectors and other products. We are a wholly - owned subsidiary of Qingdao ALPTEC Safety Equipment CO.,LTD, and committed to de velopment, sales and service of infrared principle gas detection products. We promote the development of gas detection products through continuous innovation. Through research and breakthroughs in infrared spectroscopy technology, we launched long lifetime , water vapor resistant, and highly applicable infrared gas detector products and Remote Methane Leak Detector with the features of high sensitivity and ultra - long detection range. The performance and key indicators have reached the international leading l evel. At present, our gas detection products have been recognized by our customers for the high quality and good service, and they play an active role in petrochemical, natural gas and other fields. Therefore, whether in the past or in the future, we will focus on the field of gas detection, take customers’ satisfaction as the ultimate goal, use reliable products to eliminate hidden dangers caused by dangerous gases, and protect customers’ security with sincere service.

14. ARD2 1 00 Remote Methane Leak Detector User Manual 11 4.3.5 H istorical D ata On the main menu interface, move the cursor with the + and - buttons to select the historical data icon, and press MENU to view the historica l data. Press the MENU key to confirm the historical data and return to the main menu. The historical data stores the detection data records of the last 30 times. 4.3.6 R eset On the main menu interface, move the cursor with the + and - buttons to selec t th e factory reset icon, and press MENU to enter the factory reset. Press MENU to restore the factory and return to the main menu.

13. ARD2 1 00 Remote Methane Leak Detector User Manual 10 On the main menu interface, move the cursor with the + and - keys to select the sound setting icon, and press the MENU to en te r the sound setting. Use the + and - keys to turn the sound on and off. Press MENU to confirm the changes and return to the main menu . 4.3.4 Calibration: On the main menu interface, move the cursor with the + and - buttons to select the calibration setting i con, and press the MENU key to enter the calibration setting. Press the MENU key to confirm the system. Within 10 seconds of the countdown, place the device directly in the calibration gas cell in the safety protection box. After three minutes, the calib ra tion is successful, the device alarms, remove the device, and the calibration is complete.

11. ARD2 1 00 Remote Methane Leak Detector User Manual 8 Offset setting : Use the + and - keys to change the offset value. Press MENU to con firm the changes and return to the main menu. When the device is in a known stable high - concentration methane environment and in environments with poor long - range reflective conditions, the offset setting can be used to eliminate the known environmental concentration values and background noise measurements in poorly reflective environments, and then detect maximum methane leaks. After the offset value is set, there will be an offset icon prompt in the lower right cor ner of the main menu interface. Dist ance setting: Use the + and - keys to change the distance value. Press MENU to confirm the changes and return to the main menu.

20. ARD2 1 00 Remote Methane Leak Detector User Manual 17 When the device shows a temperature control failure, yo u can try to restart the device and observe whether the device contin ues to have such failure. If the failure continues to occur, you should contact our after - sales department. ☆ Light intensity is too weak for a long time When the device shows that the lig ht intensity is too weak for a long time, first of all, check whether there are large particles blocking the laser emission port. If there is no blocking of the laser emission port, please contact our after - sales department . ☆ For other failures not listed, please contact our after - sales department 6. Routine M ainten ance In order to keep the equipment in good condition, maintenance should be performed

4. ARD2 1 00 Remote Methane Leak Detector User Manual 1 Warnings Before using the instrument, you must read the instruction manual carefully and strictly follow the s teps to operate and maintain! The handheld detect or has two lasers. When the device is turned on, the detect or laser is invisible and continuous. By pressing the switch button on the device, the green spotter laser can be turned off. The green indicating laser level is C lass 3R. Protect your eyes from di rect exposure ! Laser specifications D etect or laser : Maximum output power :≤10mW Wavelength: 1653nm Laser Class: Class 1 Spotter laser : Output power : ≤5mW Wavelength: 530nm Laser level: Class3R, direct exposure is potentially dangerous, avoid direct exposure to eyes

21. ARD2 1 00 Remote Methane Leak Detector User Manual 18 7. After - sales S ervice One - year warranty and lifetime upgrade maintenance . If you have problems during use, please contact our company. Maintenance project Frequency Wipe the exterior surface of the instrument with a damp cleaning clot h Often Clean the window of the handheld detector with an alcohol - ba sed glass cleaning cloth When the window has obvious dust and pollutants Calibration Once a month Charge End of each use

17. ARD2 1 00 Remote Methane Leak Detector User Manual 14 ☆ Common m isuses The detect or laser is facing the sky, and the light signal cannot be returned; The detect or laser is directed at the glass at a vertical angle, and the optical signal interferes, causing a false alarm. Therefore, there must be a certain an gle with t he glass when testing through the glass; During the detection, the moving speed is too fast, causing a sudden change in the signal and easily causing false alarms; The detection distance is less than 1 meter. At this time, the laser optical syste m is in a poor state. Try to avoid measuring in this state. ☆ When there are factors that cause rapid gas diffusion, such as high winds and high temperatures, the gas cannot be concentrated, which affects the detection effect. Operators should consider similar situa tions in actual operations. ☆ ARD2 1 00 Remote Metha ne Leak Detector can detect methane leakage at a limit distance of 100 meters. The actual detection limit distance will vary depending on the environment. The longer the distance, the weaker the reflected l aser energy and the lower the accuracy of the dete ction result. When abnormal changes in the alarm value are found at a long distance, you should move to a close distance and check carefully. ☆ When the detect or laser is blocked by some objects, the distanc e will be abruptly changed, and false alarms may occur.

16. ARD2 1 00 Remote Methane Leak Detector User Manual 13 4.4.2 Detecting When the laser emitted by the device passes through the natural gas leaking air mass, the methane gas will absorb the laser. The absorbed laser l igh t is received by the detector through diffuse reflection, and the concentration information of the methane gas leakage is obtained through data collection and processing. Column density of m ethane (ppm ﹒ m) = methane concentration (ppm) × air mass thickness (m). ☆ I n order to ensure that the ARD2 1 00 Remote Methane Leak Detector can properly detect methane gas, the following conditi ons must be met: There is methane gas accumulation in the laser path; Th e laser can pass through the gas; The laser can be reflected back to the receiver through the reflective surface; ☆ During the detection operation, the moving speed of the handheld det ector will also affect the detection result. Please observe the followin g points during operation: You should try to maintain a uniform moving scan; Focus on the detection of leaking valve ports, exhaust ports, cracks, etc .; When the position of the pipel ine is known, detect according to the S - shaped scanning path;

5. ARD2 1 00 Remote Methane Leak Detector User Manual 2 1. Introduction ARD2 1 00 Remote Methan e Leak Detector uses international advanced tunable diode laser absorption spectroscopy technology (TDLAS), which can detect methane gas within a certain distance. At the same time, through optimization design and independent research and development, the detection distance and accuracy of the detector are greatly improved, which is the most powerful safety guarantee for gas inspection and leak detection. Unlike traditional portable detectors, this Remote Methane Leak Detector do es not need to place the p ro be in a gas - filled environment. Instead, the device emits a laser beam. The laser passes through the pipe or the space above the facility and hits the object at the other end. Reflected back to the receiver, and then converted into electrical signals, th es e signals are used to analyze the concentration of metha ne, the unit is ppm ﹒ m. By using WMS technology, the ARD2 1 00 Remote Methane Leak Detector can achieve extremely high detection accuracy. The light at this wavelength is only absorbed by methane, so it only reacts to methane and is not affected by other gase s, which greatly impro ves the accuracy of detection. Using the Remote Methane Leak Detector , the operator does not need to be in a dangerous environment, which not only protects the safety of the inspector, but also can inspect the overhead pipeline from a long distance, which improves the inspection efficiency. The detection reading is the product of the concentration of the laser passing through the methane gas mass and the thickness of the gas mass in ppm ﹒ m, as shown below:

12. ARD2 1 00 Remote Methane Leak Detector User Manual 9 The distance can be set from 1 t o 10, corresponding to the ARD2 1 00 detection distance from near to far. For example, when measur in g a nearby pipeline or other nearby unknown leaks, you can set the distance value to 1 to improve near - site measurement accuracy; when detecting a distant leak or a high - rise building, you can increase the distance value to increase the detection distanc e. Responding speed: Use the + and - keys to change the response speed. Press MENU to confirm the changes and return to the main menu. The distance setting can be set to "fast", "medium" and "slow", correspondin g to the response speed of ARD2 1 00 from fast to s low. Unit setting : Use the + and - keys to change the unit setting. Press MENU to confirm the changes and return to the main menu. Unit setting can be set to "ppm", "% LEL" or "% VOL". Language setting : Change the language setting with the + and - keys. Pres s MENU to confirm the changes and return to the main menu. The language can be set to "Chinese" or "English". 4.3.3 Voice setting:

15. ARD2 1 00 Remote Methane Leak Detector User Manual 12 4.4 Detecting Methods 4.4.1 Aiming instructions The ARD21 00 Remote Methane Leak Detector has two aiming methods to assist d etec tion. The first is a green spotter laser. The green spotter laser is suitable for short - range aiming and aiming in weak sunlight. The second is a sight lens , which is suitable for long - distance sighting and sighting in strong sunlight. ☆ Indicating la ser aiming After the device is turned on, the spotter laser and dete ct or laser are turned off . Short press the power switch on the front of the device to turn on the spotter laser and detect or laser at the same time. ☆ Sight lens use effect When the devic e is turned on, the sight lens is also open, and when the device is turned off, the sight lens is off at the same time. The specific aiming effect is as follows: ☆ Sight lens deviation adjustment When deviation of the sight lens is found, the accuracy can be corrected by adjusting the crews in up dan down direction or left and right direction.

19. ARD2 1 00 Remote Methane Leak Detector User Manual 16 ☆ When the laser passes through a thin PE pipe, the detec t or laser may penetrate the PE pipe to detect the methane gas in the pipe, and the pipeline detection should be avoided at this time. 4.4. 3 A larm I nformation A larm of concentration When the ARD2 1 00 Remote Methane Leak laser detects a methane gas (ppm ﹒ m) that exceeds a set threshold, it will send an audible alarm signal thro ugh a buzzer, and the alarm value will be displayed on the LCD. light intensity is too weak / too strong alarm When the reflected li ght signal received by the ARD2 1 00 Remote Methane Leak Detector is too weak or too strong ( detection accuracy cannot b e guaranteed), the LCD screen displays "light intensity too weak / light intensity too strong". Temperature control fault alarm When the ARD2 1 00 Remote Methane Leak Detector detects a problem with the internal laser temperature control (which will cause inaccurate detection and affect its life), it will display a temp erature control failure on the LCD screen. 5. Common P roblems and S olutions ☆ Unable to detect known methane gas When the device does not display any alarm information, but cannot send an alarm when the known methane gas is detected, you should use the gas chamber provided with the device for calibration. For the calibration method, refer to section 4.3.3. ☆ Temperature control failure

3. ARD2 1 00 Remote Methane Leak Detector User Manual Contents Warnings ................................................... ....................................... .. ... ... ... . 1 1. Introduction ................................................................................. ... . .. ... .. 2 2. Composition........................................................................ . . ... . ... . ... . ... .. .3 3. Specifications ............... ............. ............................................. . ... .. ... ... . ... . .4 4. Operation Instruction ............................................................ . ...... .. ... . . .. .5 4.1 T urn on and Tur n of f ............................................................ .. ... ... ...... .. .5 4.2 Menu Illustration ........................ ............... ..................... . . ... .. ... . ... ... ... .. .6 4.3 Change Menu Setting ........................ ............ . ............... ... . ... . ... ... ... . ...... 6 4.3.1 Alarm Setting ........................ .............................. . ...... ... ... . . ... ... . ... . ... . ..7 4.3.2 System Setting ............... ....................................... . ...... ... .. ... . . ... ... ... . ... 7 4.3 .3 Voice Setting ...... ............................................................ . ......... ... .. ... . ..9 4.3.4 Calibration ...... ............................................................... . ......... ... ... ... . ..10 4.3.5 Historical Data ...... ............................................................ . ... . ... .. . ... ... .11 4.3.6 Reset ............ ............................................................ . ......... . .. ...... .. . ... ... 11 4.4 Detecting M ethods .................. .................. ... ... ... ............... ...... .. .. ... . ... ..11 4.4.1 Aiming Instructions .................................................................. . .. . ... ...11 4.4.2 Detecting ...................................................... .. ........................... . .. .. ... ..13 4.4.3 Alarm Information ............................................................... . . ...... ... .. .15 5. Common Problems a nd Solutions ............... ........................... .. ... . ...... .. .16 6. Routine Maintenance .................................................................. . ...... .. ... 17 7. After - Sales Service .............................................................................. ... .. 17