6. DuPont Personal Protection DuPont de Nemours (Luxembourg) S.àr.l. L-2984 Luxembourg Tel.: +800 3666 6666 (international toll-free) Fax: +352 3666 5071 E-mail: personal.protection@lux.dupont.com For further product information, literature and as well as assistance in locating a local supplier, please visit: www.safespec.dupont.co.uk The footnotes can be found on the SafeSPEC™ website. Copyright © 2019 DuPont de Nemours Inc. All rights reserved. The DuPont Oval Logo, DuPont™, and all products denoted with ® or ™ are trademarks or registered trademarks of DuPont or its affiliates. Technical_Description_101020.pdf printed on October 7, 2019 page of 6 6

5. Important Note The permeation data published have been generated for DuPont by independent accredited testing laboratories according to the test method applicable at that time (EN ISO 6529 (method A and B), ASTM F739, ASTM F1383, ASTM D6978, EN369, EN 374-3) The data is typically the average of three fabrics samples tested. All chemicals have been tested at an assay of greater than 95 (w/w) % unless otherwise stated. The tests were performed between 20 °C and 27°C and at environmental pressure unless otherwise stated. A different temperature may have significant influence on the breakthrough time. Permeation typically increases with temperature. Cumulative permeation data have been measured or have been calculated based on minimum detectable permeation rate. Cytostatic drugs testing has been performed at a test temperature of 27°C according to ASTM D6978 or ISO 6529 with the additional requirement of reporting a normalized breakthrough time at 0.01 μg/cm²/min. Chemical warfare agents (Lewisite, Sarin, Soman, Mustard, Tabun and VX Nerve Agent) have been tested according to MIL-STD-282 at 22°C or according to FINABEL 0.7 at 37°C. Permeation data for Tyvek® is applicable to white Tyvek® 500 and Tyvek® 600 only and is not applicable for other Tyvek® styles or colours. Permeation data are usually measured for single chemicals. The permeation characteristics of mixtures can often deviate considerably from the behaviour of the individual chemicals. The permeation data for gloves published have been generated according to ASTM F739 and to ASTM F1383. The degradation data for gloves published have been generated based on a gravimetric method. This degradation testing exposes one side of the glove material to the test chemical for four hours. The percent weight change after exposure is measured at four time intervals: 5, 30, 60 and 240 minutes. Degradation Ratings: • E: EXCELLENT (0-10% Weight Change) • G: GOOD (11-20% Weight Change) • F: FAIR (21-30% Weight Change) • P: POOR (31-50% Weight Change) • NR: NOT RECOMMENDED (Above 50% Weight Change) • NT: NOT TESTED Degradation is the physical change in a material after chemical exposure. Typical observable effects may be swelling, wrinkling, deterioration, or delamination. Strength loss may also occur. Please use the permeation data provided as a part of the risk assessment to assist with the selection of a protective fabric, garment, glove or accessory suitable for your application. Breakthrough time is not the same as safe wear time. Breakthrough times are indicative of the barrier performance, but results can vary between the test methods and laboratories. Breakthrough time alone is insufficient to determine how long a garment may be worn once the garment has been contaminated. Safe user wear time may be longer or shorter than the breakthrough time depending on the permeation behaviour of the substance, the toxicity of the substance, working conditions and the exposure conditions (e.g. temperature, pressure, concentration, physical state). Latest Update Permeation Data: 15/03/2019 The information provided herein corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials or additives or in any process, unless expressly indicated otherwise. The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as a license to operate under or a recommendation to infringe any patent rights. The information provided herein corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials or additives or in any process, unless expressly indicated otherwise. The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as a license to operate under or a recommendation to infringe any patent rights. Technical_Description_101020.pdf printed on October 7, 2019 page of 5 6

1. Technical Data Sheet DuPont Tyvek® IsoClean® unhooded coverall model IC 183 B WH DS. Clean-processed and gamma-sterilized. Bound internal seams. Tunnelled elastication at wrists and ankles. Elasticated waist at back. Tyvek® covered elasticated thumb loops. Zipper closure. Storm flap. Aseptically folded. CE-certified. White. Certifications Certified according to Regulation (EU) 2016/425 Chemical protective clothing, Category III, Type 5-B and 6-B EN 14126 (barrier to infective agents), EN 1073-2 (protection against radioactive contamination) Packaging(Quantity/Box) 25 per box, individually double packed. 2 polyethylene liners. Cardboard box. SAL SAL Option DS EN 14126 EN 1073-2 T6 T5 CAT III Technical Data Sheet DuPont™ Tyvek® IsoClean® , Model IC 183 B WH DS Product Size Article Number Additional info SM D15429648 MD D15429659 LG D15429666 XL D15429671 2X D15429681 3X D15429690 Full Part Number: IC0183BWHDS Technical_Description_101020.pdf printed on October 7, 2019 page of 1 6

3. COMFORT Property Test Method Result EN Air Permeability (Gurley method) ISO 5636-5 Yes N/A Air Permeability (Gurley method) ISO 5636-5 4 s N/A Thermal Resistance, Rct EN 31092/ISO 11092 10*10 m *K/W -3 2 N/A Thermal Resistance, clo value EN 31092/ISO 11092 0.065 clo N/A Water Vapour Resistance, Ret EN 31092/ISO 11092 6.8 m *Pa/W 2 N/A  According to EN 14126 2  Front Tyvek ® / Back 5  Larger than >  Smaller than <  Not Applicable N/A PENETRATION AND REPELLENCY Property Test Method Result EN Repellency to Liquids, Sodium Hydroxide (10%) EN ISO 6530 >90 % 2 of 3 1 Repellency to Liquids, Sulphuric Acid (30%) EN ISO 6530 >95 % 3 of 3 1 Resistance to Penetration by Liquids, Sodium Hydroxide (10%) EN ISO 6530 <5 % 2 of 3 1 Resistance to Penetration by Liquids, Sulphuric Acid (30%) EN ISO 6530 <1 % 3 of 3 1  According to EN 14325 1  Larger than >  Smaller than < BIOLOGICAL BARRIER Property Test Method Result EN Resistance to Penetration by Biologically Contaminated Aerosols ISO/DIS 22611 Pass 1 of 3 2 Resistance to Penetration by Blood and Body Fluids using Synthetic Blood ISO 16603 Pass 3 of 6 2 Resistance to Penetration by Blood-borne Pathogens using Bacteriophage Phi-X174 ISO 16604 Procedure C No classification No classification 2 Resistance to Penetration by Contaminated Liquids EN ISO 22610 Pass 1 of 6 2 Resistance to Penetration by Contaminated Solid Particles ISO 22612 Pass 1 of 3 2  According to EN 14126 2  Larger than >  Smaller than < CLEANILESS Property Test Method Result EN Bacterial Filtration Efficiency (3 μm) ASTM F2101 98.4 % ± 0.9 % STD DEV N/A Particle Shedding (Helmke Drum) IEST-RP-CC003.4. Category I N/A  Front Tyvek ® / Back 5  Larger than >  Smaller than <  Not Applicable N/A  Standard Deviation STD DEV Technical_Description_101020.pdf printed on October 7, 2019 page of 3 6

4. Permeation Data for Tyvek® IsoClean® Hazard / Chemical Name Physical State CAS BT Act BT 0.1 BT 1.0 EN SSPR MDPR Cum 480 Time 150 ISO Carboplatin (10 mg/ml) Liquid 441575-94-4 >240 >240 >240 5 <0.001 0.001 Carmustine (3.3 mg/ml, 10 % Ethanol) Liquid 154-93-8 imm imm >240 5 <0.3 0.001 Cisplatin (1 mg/ml) Liquid 15663-27-1 >240 >240 >240 5 <0.001 0.001 Cyclo phosphamide (20 mg/ml) Liquid 50-18-0 >240 >240 >240 5 <0.008 0.008 Doxorubicin HCl (2 mg/ml) Liquid 25136-40-9 >240 >240 >240 5 <0.001 0.001 Etoposide (Toposar®, Teva) (20 mg/ml, 33.2 % (v/v) Ethanol) Liquid 33419-42-0 >240 >240 >240 5 <0.01 <0.01 Fluorouracil, 5- (50 mg/ml) Liquid 51-21-8 imm imm imm na 0.001 Gemcitabine (38 mg/ml) Liquid 95058-81-4 imm >60 >240 5 <0.4 0.005 Ifosfamide (50 mg/ml) Liquid 3778-73-2 >240 >240 >240 5 <0.009 0.009 Oxaliplatin (5 mg/ml) Liquid 63121-00-6 imm imm imm na 0.001 Paclitaxel (Hospira) (6 mg/ml, 49.7 % (v/v) Ethanol) Liquid 33069-62-4 >240 >240 >240 5 <0.01 <0.01 Thiotepa (10 mg/ml) Liquid 52-24-4 imm imm imm na 0.001 BTAct (Actual) Breakthrough time at MDPR [mins] BT0.1 Normalized breakthrough time at 0.1 μg/cm²/min [mins] BT1.0 Normalized breakthrough time at 1.0 μg/cm²/min [mins] EN Classification according to EN 14325 SSPR Steady state permeation rate [μg/cm²/min] MDPR Minimum detectable permeation rate [μg/cm²/min] CUM480 Cumulative permeation mass after 480 mins [μg/cm²] Time150 Time to reach cumulative permeation mass of 150 μg/cm² [mins] ISO Classification according to ISO 16602 CAS Chemical abstracts service registry number min Minute > Larger than < Smaller than imm Immediate (< 10 min) nm Not tested sat Saturated solution N/A Not Applicable na Not attained GPR grade General purpose reagent grade * Based on lowest single value 8 Actual breakthrough time; normalized breakthrough time is not available DOT5 Degradation after 5 min DOT30 Degradation after 30 min DOT60 Degradation after 60 min DOT240 Degradation after 240 min BT1383 Normalized breakthrough time at 0.1 μg/cm²/min [mins] acc. ASTM F1383 Technical_Description_101020.pdf printed on October 7, 2019 page of 4 6

2. PHYSICAL PROPERTIES Property Test Method Result EN Abrasion Resistance 7 EN 530 Method 2 >10 cycles 1 of 6 1 Basis Weight DIN EN ISO 536 45 g/m 2 N/A Colour N/A White N/A Exposure to high Temperature N/A Melting point ~135 °C N/A Flex Cracking Resistance 7 EN ISO 7854 Method B >100000 cycles 6 of 6 1 Puncture Resistance EN 863 >5 N 1 of 6 1 Resistance to Water Penetration DIN EN 20811 7 kPa N/A Surface Resistance at RH 25%, inside 7 EN 1149-1 2 Ohm 10 N/A Tensile Strength (MD) DIN EN ISO 13934-1 >30 N 1 of 6 1 Tensile Strength (XD) DIN EN ISO 13934-1 >30 N 1 of 6 1 Thickness DIN EN ISO 534 185 μm N/A Trapezoidal Tear Resistance (MD) EN ISO 9073-4 >10 N 1 of 6 1 Trapezoidal Tear Resistance (XD) EN ISO 9073-4 >10 N 1 of 6 1  According to EN 14325 1  According to EN 14126 2  According to EN 1073-2 3  According to EN 14116 4   According to EN 11612 12  Front Tyvek ® / Back 5  Based on test according to ASTM D-572 6  See 7 Instructions for Use for further information, limitations and warnings  Larger than >  Smaller than <  Not Applicable N/A  Standard Deviation STD DEV GARMENT PERFORMANCE Property Test Method Result EN Nominal protection factor 7 EN 1073-2 >50 2 of 3 3 Seam Strength EN ISO 13935-2 >30 N 1 of 6 1 Shelf Life 7 N/A 5 years N/A Type 5: Inward Leakage 11 EN ISO 13982-2 3 % N/A Type 5: Inward Leakage of Airborne Solid Particulates EN ISO 13982-2 Pass N/A Type 6: Resistance to Penetration by Liquids (Low Level Spray Test) EN ISO 17491-4, Method A Pass N/A  According to EN 14325 1  According to EN 1073-2 3   According to EN 11612 12   According to EN 11611 13  Front Tyvek ® / Back 5  Based on test according to ASTM D-572 6  See Instructions for Use for 7 further information, limitations and warnings  Based on the average of 10 suits, 3 activities, 3 probes 11  Larger than >  Smaller than <  Not Applicable N/A  Based on lowest single value * Technical_Description_101020.pdf printed on October 7, 2019 page of 2 6